MyLoc

Highest reliability, energy efficiency and noise reduction

  • MyLoc

  • Germany, Düsseldorf

  • CyberAir 3

  • Requirement to improve availability

  • Cooling system in line with the very latest standards

  • 810 kW

The Customer

MyLoc managed IT AG has three data centers in Düsseldorf covering a total surface area of 2,500 m². The company, which was established back in 1999, has been a subsidiary of Medienholding virtual minds AG since 2006, and offers its business and private customers innovative hosting solutions in the field of colocation and managed service products. The availability of its data centers is one of myLoc managed IT AG's highest priorities. In the world's largest Lampertz security room designed to LSR18.6 standards, sensitive systems from major clients such as banks, insurance companies and ISPs are protected, primarily from external influences, as a colocation arrangement. Here, more than 300 colocation customers can rely on high reliability thanks to the proactive monitoring system and the sustainable, redundant setup of all the relevant systems. 

The challenge
Our solution
The result
Contact us

MyLoc managed IT AG needed to improve the crucial aspect of availability still further. In addition, it wanted the energy efficiency of the cooling system to be brought in line with the very latest standards. To this aim, the aging closed-circuit air conditioning system (without Free Cooling function) and recooling heat exchangers had to be dismantled and replaced by a completely new system. The work had to be performed during ongoing operation without jeopardizing existing data center services. 

 

The requirements for the new, fully integrated concept were, firstly, to achieve a certain independence and certainty in the calculation of energy costs that fluctuate strongly and are generally on the rise. A second objective was to be able to offer customers of myLoc the maximum possible reliability. Furthermore, impact on the environment through noise emissions had to be kept to a minimum, as the data center is situated in the residential mixed-use zone of the provincial capital, Düsseldorf. 

The solution that meets these demanding requirements is an operator concept using local energy suppliers, the Düsseldorf public utilities. The concept incorporates electricity generation from a cogeneration plant powered by natural gas and employs the waste heat from this plant for cooling using so-called trigeneration (combined heat and power and cooling). An arrangement of this nature sets extremely stringent demands for the air conditioning solution. Therefore, ten STULZ CyberAir3 units of the type ALD 812 GE were installed for the new data center. Each air conditioning cabinet accommodates two coils: one direct cooler in the form of a chilled water coil, and one evaporator.

In normal operation, the chilled water from the absorption chiller flows through the direct cooler of the air conditioning cabinet, cooling the data center in the process. If this is not the case, e.g. due to maintenance work, each unit has its own liquid cooled chilling function with a capacity of approx. 80 kW. This way, the air conditioning cabinets can automatically take over the air conditioning of the data center without interruption, if required. In a collaborative undertaking involving myLoc, the Düsseldorf public utilities and STULZ, the chilling system was converted during ongoing operation. 

With the completion of the conversion work, myLoc managed IT AG has a fully integrated energy concept, so that it can now look forward to considerably reduced and predictable, fixed energy costs for the next 10 years. Thanks to the innovative redundant setup, the cooling systems can be serviced independently from one another without any interruption to operation. 

 

 

The contracting model with the Düsseldorf public utilities has the advantage of providing a point of contact for all aspects of electricity supply and cooling. The environment also benefits from the advanced energy concept, with a reduction in CO2 emissions of 830 tons, for example.

Contact us directly

Do you have a similar challenge or even something completely different?

Our experts will be happy to assist you with a thorough analysis and competent advice.
 

Contact us now

Together we achieve your goals

The CyberAir 3PRO DX room air conditioner is the result of more than three decades of experience with projects around the world, and is the logical next step in the development of the successful CyberAir 3 series. To achieve maximum cooling capacity with a minimal footprint while promising you maximum potential savings, these HVAC system units are more adaptable than any other precision air conditioning unit on the market.
 


Individual solutions with STULZ

You are looking for an individually configured solution for the efficient cooling of your project?

Our qualified experts will be happy to support you with an in-depth analysis and competent advice.

Get in contact
Your Company
Personal data
Mrs. Mr. Diverse
Åland Afghanistan Albania Algeria American Samoa Andorra Angola Anguilla Antarctica Antigua and Barbuda Argentina Armenia Aruba Australia Austria Azerbaijan Bahrain Bangladesh Barbados Belarus Belgium Belize Benin Bermuda Bhutan Bolivia Bonaire, Sint Eustatius and Saba Bosnia and Herzegovina Botswana Bouvet Island Brazil British Indian Ocean Territory British Virgin Islands Brunei Bulgaria Burkina Faso Burundi Cambodia Cameroon Canada Cape Verde Cayman Islands Central African Republic Chad Chile China Christmas Island Cocos (Keeling) Islands Colombia Comoros Congo Congo-Brazzaville Cook Islands Costa Rica Croatia Cuba Curaçao Cyprus Czech Republic Côte d’Ivoire Denmark Djibouti Dominica Dominican Republic Ecuador Egypt El Salvador Equatorial Guinea Eritrea Estonia Eswatini Ethiopia Falkland Islands Faroes Fiji Finland France French Guiana French Polynesia French Southern Territories Gabon Gambia Georgia Germany Ghana Gibraltar Greece Greenland Grenada Guadeloupe Guam Guatemala Guernsey Guinea Guinea-Bissau Guyana Haiti Heard Island and McDonald Islands Honduras Hong Kong SAR of China Hungary Iceland India Indonesia Iran Iraq Ireland Isle of Man Israel Italy Jamaica Japan Jersey Jordan Kazakhstan Kenya Kiribati Kosovo Kuwait Kyrgyzstan Laos Latvia Lebanon Lesotho Liberia Libya Liechtenstein Lithuania Luxembourg Macao SAR of China Madagascar Malawi Malaysia Maldives Mali Malta Marshall Islands Martinique Mauritania Mauritius Mayotte Mexico Micronesia Moldova Monaco Mongolia Montenegro Montserrat Morocco Mozambique Myanmar Namibia Nauru Nepal Netherlands New Caledonia New Zealand Nicaragua Niger Nigeria Niue Norfolk Island Northern Marianas North Korea North Macedonia Norway Oman Pakistan Palau Palestine Panama Papua New Guinea Paraguay Peru Philippines Pitcairn Islands Poland Portugal Puerto Rico Qatar Reunion Romania Russia Rwanda Saint Barthélemy Saint Helena, Ascension and Tristan da Cunha Saint Kitts and Nevis Saint Lucia Saint Martin Saint Pierre and Miquelon Saint Vincent and the Grenadines Samoa San Marino Saudi Arabia Senegal Serbia Seychelles Sierra Leone Singapore Sint Maarten Slovakia Slovenia Solomon Islands Somalia South Africa South Georgia and the South Sandwich Islands South Korea South Sudan Spain Sri Lanka Sudan Suriname Svalbard Sweden Switzerland Syria São Tomé e Príncipe Taiwan Tajikistan Tanzania Thailand The Bahamas Timor-Leste Togo Tokelau Tonga Trinidad and Tobago Tunisia Turkey Turkmenistan Turks and Caicos Islands Tuvalu Uganda Ukraine United Arab Emirates United Kingdom United States United States Minor Outlying Islands Uruguay US Virgin Islands Uzbekistan Vanuatu Vatican City Venezuela Vietnam Wallis and Futuna Western Sahara Yemen Zambia Zimbabwe
I agree that my data will be forwarded to an authorized STULZ subsidiary or partner responsible for my country to answer my request.
I have read and accepted theData Protection Declaration . *

*Mandatory field