Integrated Liquid Cooling System

Integrated liquid cooling system

Efficient Liquid Cooling solution for IT loads up to 100 kW per rack

Our solution, equipped with integrated Direct Chip Liquid Cooling (DCLC), is a standardized, row-style modular data center designed for high-density applications. It combines air and liquid cooling from a single source, ensuring optimal performance for IT loads up to 100 kW per rack.

Manufactured, fully tested, and ready for deployment, this modular data center offers customers peace of mind.

Liquid Cooling Data Center Units immediately ready for connection and operation Scalability

Liquid Cooling System Overview

Climate. Customized.

At our core, we are committed to providing a flexible and tailored solution to meet your specific needs. Through a highly adaptable system of standardized components, we enable a wide range of configurations that can be customized to suit different operational requirements.

Liquid cooling solution with integrated Direct Chip Liquid Cooling (DCLC)

Energy efficiency & reliability

High Efficiency

  • Extremely low pPUE (~1.02 at full load) for optimal energy performance
  • Year-round Free Cooling possible depending on TCS water temperature specifications
  • Energy-efficient inverter components, including EC fans and inverter pumps, eliminating the need for liquid bypass
  • Slightly oversized pipes reduce pump power consumption, enhancing overall efficiency

 

High Reliability

  • Verified by third-party performance reports (noise, EMC, and pPUE) ensuring transparency and reliability
  • Optional redundant configuration of critical components (power supply, pumps, EC fans)
  • Redundant sensorics for key features
  • High-quality liquid maintained with sanitary-grade stainless steel pipes and a built-in filter on the TCS side preserving 50 μm water cleanliness
  • Optional 25 μm filter on the TCS side
  • Integrated anti-condensation function
  • Room neutral cooling: racks do not release heat into the IT room
  • Leak detection
High efficiency and reliability of STULZ Liquid Cooling systems

Fast and easy deployment

The integrated Liquid Cooling system is designed for rapid deployment, with setup completed in one day. It includes pre-installed piping for the Technical Cooling System (TCS) and Facility Water System (FWS), requiring only a quick connection to the pump and dry cooler. No additional components or chiller are necessary, making this a streamlined and efficient solution for your cooling needs.

 

Components

  1. Control system with integrated monitoring system
  2. CyberCool CMU Coolant distribution unit (CDU)
  3. Technical Cooling System (TCS)
  4. Pre-installed piping for Technical Cooling System (TCS) and Facility Water System (FWS)
  5. DCLC racks with manifolds for 80 % Liquid Cooling
  6. Power Distribution Unit (PDU)
  7. CyberRack Active Rear Doors (air-cooled) for the remaining 20 % of the cooling requirement

 

Components: This all-in-one system was designed with all the essential components to deliver a comprehensive and reliable solution for your specific application needs.

Liquid cooling system designed for easy and rapid deployment

Precise control for greater reliability

Thanks to its flexible and precise control, the integrated Liquid Cooling sytems ensures maximum reliability during continuous operation. In addition, to achieve the highest standards of reliability and usability, STULZ develops the controller in house, ensuring that software, hardware and liquid cooling units are perfectly harmonized.

 

Other advantages

  • Precise coolant temperature control with ±0.5°C accuracy
  • Supports both cold standby and hot standby modes
  • Monitors, calculates, and displays water flow and cooling capacity for CyberRack Active Rear Doors
  • Provides real-time monitoring, calculation, and display of power supply and pPUE data
  • Compatible with RS485, RJ45 ports, and multiple protocols including Modbus RTU, Modbus TCP/IP, BACnet IP, SNMP, HTTP, and more
  • Features advanced monitoring and alarms for PH value, water conductivity, and water leakage detection
Precise control for greater reliability

Scalability

This solution’s modular design enables the seamless integration of multiple units while allowing the option to include a redundant CDU for enhanced reliability and performance. With this flexible configuration, you can easily adapt to your specific capacity and reliability requirements, all while maintaining scalability and operational efficiency.

Technical parameters can be selected and verified according to the customer’s actual operating conditions. If you require technical data, please contact STULZ

Solution's modular design

Fast service and maintenance

Our trained and experienced sales and service partners are available in over 150 countries. The resulting proximity to our customers enables rapid reaction times.

  • Front and rear access for easy maintenance of all components
  • Reduced operational components with integrated air and liquid cooling from a single source
  • Supports online maintenance for all inbuilt filters
  • Quick-clamp connections for fast pipe setup
  • Shut-off valves before and after pumps and filters
  • Automatic fill level control for TCS loop
Service and maintenance for air and liquid cooling solutions
Professional service worldwide

Fast response times and regular trainings to ensure high quality of our products

Liquid Cooling System Flyer

Need more information?

Download our brochure!

  • Download

Learn more about Liquid Cooling

STULZ is international

Close to you around the world

With 23 subsidiaries comprising 11 production sites and 12 sales companies in Africa, America, Asia, Europe and Oceania, the company is at your side at all times. In addition, STULZ has exclusive agreements with numerous sales and service partners on all continents and is therefore represented in over 150 countries around the globe. With this global network of partners and independent manufacturers for direct chip and immersion cooling, STULZ is the right partner for all liquid cooling requirements.


Interest
Åland Afghanistan Albania Algeria American Samoa Andorra Angola Anguilla Antarctica Antigua and Barbuda Argentina Armenia Aruba Australia Austria Azerbaijan Bahrain Bangladesh Barbados Belarus Belgium Belize Benin Bermuda Bhutan Bolivia Bonaire, Sint Eustatius and Saba Bosnia and Herzegovina Botswana Bouvet Island Brazil British Indian Ocean Territory British Virgin Islands Brunei Bulgaria Burkina Faso Burundi Cambodia Cameroon Canada Cape Verde Cayman Islands Central African Republic Chad Chile China Christmas Island Cocos (Keeling) Islands Colombia Comoros Congo Congo-Brazzaville Cook Islands Costa Rica Croatia Cuba Curaçao Cyprus Czech Republic Côte d’Ivoire Denmark Djibouti Dominica Dominican Republic Ecuador Egypt El Salvador Equatorial Guinea Eritrea Estonia Eswatini Ethiopia Falkland Islands Faroes Fiji Finland France French Guiana French Polynesia French Southern Territories Gabon Gambia Georgia Germany Ghana Gibraltar Greece Greenland Grenada Guadeloupe Guam Guatemala Guernsey Guinea Guinea-Bissau Guyana Haiti Heard Island and McDonald Islands Honduras Hong Kong SAR of China Hungary Iceland India Indonesia Iran Iraq Ireland Isle of Man Israel Italy Jamaica Japan Jersey Jordan Kazakhstan Kenya Kiribati Kosovo Kuwait Kyrgyzstan Laos Latvia Lebanon Lesotho Liberia Libya Liechtenstein Lithuania Luxembourg Macao SAR of China Madagascar Malawi Malaysia Maldives Mali Malta Marshall Islands Martinique Mauritania Mauritius Mayotte Mexico Micronesia Moldova Monaco Mongolia Montenegro Montserrat Morocco Mozambique Myanmar Namibia Nauru Nepal Netherlands New Caledonia New Zealand Nicaragua Niger Nigeria Niue Norfolk Island Northern Marianas North Korea North Macedonia Norway Oman Pakistan Palau Palestine Panama Papua New Guinea Paraguay Peru Philippines Pitcairn Islands Poland Portugal Puerto Rico Qatar Reunion Romania Russia Rwanda Saint Barthélemy Saint Helena, Ascension and Tristan da Cunha Saint Kitts and Nevis Saint Lucia Saint Martin Saint Pierre and Miquelon Saint Vincent and the Grenadines Samoa San Marino Saudi Arabia Senegal Serbia Seychelles Sierra Leone Singapore Sint Maarten Slovakia Slovenia Solomon Islands Somalia South Africa South Georgia and the South Sandwich Islands South Korea South Sudan Spain Sri Lanka Sudan Suriname Svalbard Sweden Switzerland Syria São Tomé e Príncipe Taiwan Tajikistan Tanzania Thailand The Bahamas Timor-Leste Togo Tokelau Tonga Trinidad and Tobago Tunisia Turkey Turkmenistan Turks and Caicos Islands Tuvalu Uganda Ukraine United Arab Emirates United Kingdom United States United States Minor Outlying Islands Uruguay US Virgin Islands Uzbekistan Vanuatu Vatican City Venezuela Vietnam Wallis and Futuna Western Sahara Yemen Zambia Zimbabwe
Åland Afghanistan Albania Algeria American Samoa Andorra Angola Anguilla Antarctica Antigua and Barbuda Argentina Armenia Aruba Australia Austria Azerbaijan Bahrain Bangladesh Barbados Belarus Belgium Belize Benin Bermuda Bhutan Bolivia Bonaire, Sint Eustatius and Saba Bosnia and Herzegovina Botswana Bouvet Island Brazil British Indian Ocean Territory British Virgin Islands Brunei Bulgaria Burkina Faso Burundi Cambodia Cameroon Canada Cape Verde Cayman Islands Central African Republic Chad Chile China Christmas Island Cocos (Keeling) Islands Colombia Comoros Congo Congo-Brazzaville Cook Islands Costa Rica Croatia Cuba Curaçao Cyprus Czech Republic Côte d’Ivoire Denmark Djibouti Dominica Dominican Republic Ecuador Egypt El Salvador Equatorial Guinea Eritrea Estonia Eswatini Ethiopia Falkland Islands Faroes Fiji Finland France French Guiana French Polynesia French Southern Territories Gabon Gambia Georgia Germany Ghana Gibraltar Greece Greenland Grenada Guadeloupe Guam Guatemala Guernsey Guinea Guinea-Bissau Guyana Haiti Heard Island and McDonald Islands Honduras Hong Kong SAR of China Hungary Iceland India Indonesia Iran Iraq Ireland Isle of Man Israel Italy Jamaica Japan Jersey Jordan Kazakhstan Kenya Kiribati Kosovo Kuwait Kyrgyzstan Laos Latvia Lebanon Lesotho Liberia Libya Liechtenstein Lithuania Luxembourg Macao SAR of China Madagascar Malawi Malaysia Maldives Mali Malta Marshall Islands Martinique Mauritania Mauritius Mayotte Mexico Micronesia Moldova Monaco Mongolia Montenegro Montserrat Morocco Mozambique Myanmar Namibia Nauru Nepal Netherlands New Caledonia New Zealand Nicaragua Niger Nigeria Niue Norfolk Island Northern Marianas North Korea North Macedonia Norway Oman Pakistan Palau Palestine Panama Papua New Guinea Paraguay Peru Philippines Pitcairn Islands Poland Portugal Puerto Rico Qatar Reunion Romania Russia Rwanda Saint Barthélemy Saint Helena, Ascension and Tristan da Cunha Saint Kitts and Nevis Saint Lucia Saint Martin Saint Pierre and Miquelon Saint Vincent and the Grenadines Samoa San Marino Saudi Arabia Senegal Serbia Seychelles Sierra Leone Singapore Sint Maarten Slovakia Slovenia Solomon Islands Somalia South Africa South Georgia and the South Sandwich Islands South Korea South Sudan Spain Sri Lanka Sudan Suriname Svalbard Sweden Switzerland Syria São Tomé e Príncipe Taiwan Tajikistan Tanzania Thailand The Bahamas Timor-Leste Togo Tokelau Tonga Trinidad and Tobago Tunisia Turkey Turkmenistan Turks and Caicos Islands Tuvalu Uganda Ukraine United Arab Emirates United Kingdom United States United States Minor Outlying Islands Uruguay US Virgin Islands Uzbekistan Vanuatu Vatican City Venezuela Vietnam Wallis and Futuna Western Sahara Yemen Zambia Zimbabwe
Data Center IT/Telecommunications Consulting/Engineering Healthcare Warehouse/Manufacturing Construction Other
Personal data
Mrs. Mr. Diverse
I want to talk to sales. I need technical support/service. I want to order parts / need a quote. I am looking for a job/interested in recruitment. I need a general information / other.
Yes, in the next 6 months Yes, in the next year No
I agree that my data will be forwarded to an authorized STULZ subsidiary or partner responsible for my country to answer my request.
I have read and accepted the Data Protection Declaration . *

*Mandatory field